Show Hamamatsu Avalanche Photo Diode 1417016421 - Archived data from Tue, 11. August 2020 17:25:59 CEST
This is all the information about APD 1417016421. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1417016421 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | F09 |
Break-through voltage: | 422 V |
Voltage for Gain 100 (T=+25°C): | 394.9 V |
Dark current: | 7.2 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 39 |
Position in Box: | 7 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 414 |
Position in grid: | 11 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | 16. Jan 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 28. Nov 2018 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 30. Nov 2018 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 394.7429258 V T = -25 °C: 358.161305 V |
Voltage for Gain 150: | T = +20 °C: 402.6461364 V T = -25 °C: 365.8740938 V |
Voltage for Gain 200: | T = +20 °C: 407.0848283 V T = -25 °C: 370.1932341 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.543659624 V-1 T = -25 °C: 4.642439335 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.645451072 V-1 T = -25 °C: 9.214309235 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 13.85005582 V-1 T = -25 °C: 14.89631483 V-1 |
Break-through voltage: | T = +20 °C: 421.7696199 V T = -25 °C: 385.1845148 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 10:53:13 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:18:59 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:25:59 CEST | jreher | Updated APD characteristics via API. |
27. Nov 2019 19:35:52 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:13:57 CET | jreher | Updated box and position via API. |
04. Jul 2019 11:10:53 CEST | jreher | Updated APD location via API. |
12. Jun 2019 16:48:18 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 16:33:14 CEST | jreher | Updated APD batch assignment via API. |
18. Jan 2019 14:33:23 CET | markus.moritz | Entered shipped after irradiation date. |
03. Dec 2018 10:32:37 CET | markus.moritz | |
29. Sep 2017 09:49:04 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:29:40 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:40:59 CEST | Tobias | Imported from Hamamatsu datasheet. |