Show Hamamatsu Avalanche Photo Diode 1417016408 - Archived data from Wed, 16. June 2021 15:51:59 CEST


This is all the information about APD 1417016408. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1417016408
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: A07
Break-through voltage: 422 V
Voltage for Gain 100 (T=+25°C): 394.8 V
Dark current: 9.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 39
Position in Box: 2
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 414
Position in grid: 2
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: 16. Jan 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Nov 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 30. Nov 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 394.6957464 V     T = -25 °C: 358.0613125 V
Voltage for Gain 150: T = +20 °C: 402.7028262 V     T = -25 °C: 365.7960556 V
Voltage for Gain 200: T = +20 °C: 407.1745061 V     T = -25 °C: 370.1089647 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.556594848 V-1     T = -25 °C: 4.798660702 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.796148659 V-1     T = -25 °C: 9.55672259 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.17209396 V-1     T = -25 °C: 14.92681339 V-1
Break-through voltage: T = +20 °C: 422.2251399 V     T = -25 °C: 385.3774558 V
   
Notes:


Version history

Time Author Change comment
19. Nov 2021 13:06:18 CET oafedulidis Assigned to capsule by script
16. Jun 2021 16:02:56 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:59:20 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:51:59 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:53:12 CET jreher Updated box and position via API.
03. Feb 2021 18:18:58 CET jreher Updated box and position via API.
11. Aug 2020 17:25:58 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:35:52 CET jreher Updated APD location via API.
25. Nov 2019 17:13:57 CET jreher Updated box and position via API.
04. Jul 2019 11:10:53 CEST jreher Updated APD location via API.
12. Jun 2019 16:48:17 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:33:13 CEST jreher Updated APD batch assignment via API.
18. Jan 2019 14:33:23 CET markus.moritz Entered shipped after irradiation date.
03. Dec 2018 10:41:19 CET markus.moritz
29. Sep 2017 09:49:04 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:40 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:40:59 CEST Tobias Imported from Hamamatsu datasheet.