Show Hamamatsu Avalanche Photo Diode 1416016377 - Archived data from Tue, 11. August 2020 17:58:52 CEST
This is all the information about APD 1416016377. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1416016377 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | B10 |
Break-through voltage: | 424 V |
Voltage for Gain 100 (T=+25°C): | 395.6 V |
Dark current: | 5.3 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 310 |
Position in Box: | 27 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 413 |
Position in grid: | 4 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | 27. Oct 2017 |
Return for assembly: | none |
Irradiation: | |
Date: | 25. Oct 2017 |
Dose used: | 45 Gy |
Temperature: | 20 °C |
Position: | 4 |
Bias voltage: | 395.6 V (connected) |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 396.3507697 V T = -25 °C: 359.9798239 V |
Voltage for Gain 150: | T = +20 °C: 404.2531586 V T = -25 °C: 367.6727613 V |
Voltage for Gain 200: | T = +20 °C: 408.6355581 V T = -25 °C: 371.9653254 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.431193308 V-1 T = -25 °C: 4.731403841 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.691534239 V-1 T = -25 °C: 9.410913575 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 15.18081563 V-1 T = -25 °C: 14.77650185 V-1 |
Break-through voltage: | T = +20 °C: 423.9662187 V T = -25 °C: 387.771074 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:28:28 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:58:52 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:45:24 CEST | jreher | Updated APD location via API. |
21. Jul 2020 14:45:15 CEST | jreher | Updated box and position via API. |
19. Dec 2019 16:48:21 CET | spankonin | Updated APD batch assignment via API. |
19. Dec 2019 15:19:09 CET | jreher | Updated box and position via API. |
27. Oct 2017 10:37:50 CEST | markus.moritz | Entered shipped after irradiation date. |
27. Oct 2017 10:36:51 CEST | markus.moritz | Entered shipped after irradiation date. |
26. Oct 2017 16:31:14 CEST | markus.moritz | Entered irradiation information. |
29. Sep 2017 14:25:38 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:29:39 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:40:58 CEST | Tobias | Imported from Hamamatsu datasheet. |