Show Hamamatsu Avalanche Photo Diode 1416016327 - Archived data from Tue, 11. August 2020 18:04:07 CEST
This is all the information about APD 1416016327. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1416016327 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | D14 |
Break-through voltage: | 422 V |
Voltage for Gain 100 (T=+25°C): | 394.6 V |
Dark current: | 6 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 285 |
Position in Box: | 43 |
EP1 batch: | 204 |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 410 |
Position in grid: | 15 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 394.7435581 V T = -25 °C: 358.4300577 V |
Voltage for Gain 150: | T = +20 °C: 402.6763069 V T = -25 °C: 366.1094665 V |
Voltage for Gain 200: | T = +20 °C: 407.0724215 V T = -25 °C: 370.4217046 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.63022571 V-1 T = -25 °C: 4.58662697 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.185166389 V-1 T = -25 °C: 9.012593117 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.25657295 V-1 T = -25 °C: 15.79437204 V-1 |
Break-through voltage: | T = +20 °C: 421.7236656 V T = -25 °C: 385.7269517 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:25:08 CET | jreher | Updated box and position via API. |
11. Aug 2020 18:04:07 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:39:54 CEST | jreher | Updated APD location via API. |
21. Jul 2020 14:39:45 CEST | jreher | Updated box and position via API. |
10. Feb 2020 18:57:10 CET | spankonin | Updated APD batch assignment via API. |
29. Nov 2019 11:50:16 CET | jreher | Updated APD location via API. |
27. Nov 2019 20:18:00 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:31:07 CET | jreher | Updated box and position via API. |
22. Oct 2019 13:10:56 CEST | spankonin | Updated APD location via API. |
09. Oct 2019 11:47:45 CEST | jgrochowski | Updated APD batch assignment via API. |
29. Sep 2017 12:26:44 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:29:37 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:40:57 CEST | Tobias | Imported from Hamamatsu datasheet. |