RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1416016320 - Archived data from Mon, 10. May 2021 14:00:31 CEST


This is all the information about APD 1416016320. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1416016320
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G06
Break-through voltage: 417 V
Voltage for Gain 100 (T=+25°C): 388.8 V
Dark current: 5.4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 285
Position in Box: 36
EP1 batch: 204
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 410
Position in grid: 8
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 389.777903 V     T = -25 °C: 353.7980802 V
Voltage for Gain 150: T = +20 °C: 397.6352037 V     T = -25 °C: 361.3228757 V
Voltage for Gain 200: T = +20 °C: 401.9844876 V     T = -25 °C: 365.5578944 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.652402466 V-1     T = -25 °C: 4.897341746 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.302465784 V-1     T = -25 °C: 8.974696763 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.57970203 V-1     T = -25 °C: 15.7560947 V-1
Break-through voltage: T = +20 °C: 414.877799 V     T = -25 °C: 380.7111217 V
   
Notes:


Version history

Time Author Change comment
26. Oct 2021 10:49:36 CEST oafedulidis Assigned to capsule by script
10. May 2021 14:00:31 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:25:07 CET jreher Updated box and position via API.
11. Aug 2020 18:04:05 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:39:53 CEST jreher Updated APD location via API.
21. Jul 2020 14:39:44 CEST jreher Updated box and position via API.
10. Feb 2020 18:57:09 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:50:16 CET jreher Updated APD location via API.
27. Nov 2019 20:18:00 CET jreher Updated APD location via API.
25. Nov 2019 17:31:06 CET jreher Updated box and position via API.
22. Oct 2019 13:10:55 CEST spankonin Updated APD location via API.
09. Oct 2019 11:47:44 CEST jgrochowski Updated APD batch assignment via API.
29. Sep 2017 12:26:44 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:37 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:40:57 CEST Tobias Imported from Hamamatsu datasheet.