RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1416016312 - Archived data from Thu, 23. June 2016 10:40:56 CEST


This is all the information about APD 1416016312. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1416016312
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: unknown
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F07
Break-through voltage: 420 V
Voltage for Gain 100 (T=+25°C): 391.4 V
Dark current: 6.3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 285
Position in Box: 28
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 150: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 200: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 100: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 150: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 200: T = +20 °C: none     T = -25 °C: none
Break-through voltage: T = +20 °C: none     T = -25 °C: none
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:25:06 CET jreher Updated box and position via API.
11. Aug 2020 18:04:03 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:39:53 CEST jreher Updated APD location via API.
21. Jul 2020 14:39:43 CEST jreher Updated box and position via API.
10. Feb 2020 18:57:08 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:50:15 CET jreher Updated APD location via API.
27. Nov 2019 20:17:59 CET jreher Updated APD location via API.
25. Nov 2019 17:31:06 CET jreher Updated box and position via API.
22. Oct 2019 13:10:54 CEST spankonin Updated APD location via API.
09. Oct 2019 11:47:44 CEST jgrochowski Updated APD batch assignment via API.
29. Sep 2017 12:26:44 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:37 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:40:56 CEST Tobias Imported from Hamamatsu datasheet.