Show Hamamatsu Avalanche Photo Diode 1416016306 - Archived data from Tue, 11. August 2020 17:40:14 CEST
This is all the information about APD 1416016306. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1416016306 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | D13 |
Break-through voltage: | 424 V |
Voltage for Gain 100 (T=+25°C): | 395.9 V |
Dark current: | 5.7 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 289 |
Position in Box: | 32 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 409 |
Position in grid: | 15 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | 22. Feb 2018 |
Dose used: | 30 Gy |
Temperature: | 25 °C |
Position: | 2 |
Bias voltage: | 0 V (connected) |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 396.2324456 V T = -25 °C: 359.6678024 V |
Voltage for Gain 150: | T = +20 °C: 404.1554614 V T = -25 °C: 367.434174 V |
Voltage for Gain 200: | T = +20 °C: 408.5647039 V T = -25 °C: 371.7684692 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.48989787 V-1 T = -25 °C: 4.468610821 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.777794928 V-1 T = -25 °C: 8.669972111 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 15.26021002 V-1 T = -25 °C: 15.0123559 V-1 |
Break-through voltage: | T = +20 °C: 423.8345216 V T = -25 °C: 387.4983865 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:25:36 CET | jreher | Updated box and position via API. |
07. Oct 2020 15:44:49 CEST | jreher | Updated APD location via API. |
11. Aug 2020 17:40:14 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:40:32 CEST | jreher | Updated box and position via API. |
27. Nov 2019 20:18:39 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:31:24 CET | jreher | Updated box and position via API. |
22. Oct 2019 14:31:15 CEST | spankonin | Updated APD location via API. |
14. Oct 2019 17:33:22 CEST | jgrochowski | Updated APD batch assignment via API. |
05. Apr 2018 12:28:22 CEST | markus.moritz | Entered irradiation information. |
29. Sep 2017 14:09:35 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:29:36 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:40:56 CEST | Tobias | Imported from Hamamatsu datasheet. |