Show Hamamatsu Avalanche Photo Diode 1415016285 - Archived data from Fri, 29. September 2017 14:09:35 CEST
This is all the information about APD 1415016285. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1415016285 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | unknown |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | A09 |
Break-through voltage: | 414 V |
Voltage for Gain 100 (T=+25°C): | 387.7 V |
Dark current: | 6.8 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 289 |
Position in Box: | 3 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 409 |
Position in grid: | 12 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
Break-through voltage: | T = +20 °C: none T = -25 °C: none |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:25:32 CET | jreher | Updated box and position via API. |
07. Oct 2020 15:44:47 CEST | jreher | Updated APD location via API. |
11. Aug 2020 17:40:07 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:40:29 CEST | jreher | Updated box and position via API. |
27. Nov 2019 20:18:37 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:31:22 CET | jreher | Updated box and position via API. |
22. Oct 2019 14:31:13 CEST | spankonin | Updated APD location via API. |
09. Oct 2019 11:30:28 CEST | jgrochowski | Updated APD batch assignment via API. |
05. Apr 2018 12:28:22 CEST | markus.moritz | Entered irradiation information. |
29. Sep 2017 14:09:35 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:29:36 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:40:56 CEST | Tobias | Imported from Hamamatsu datasheet. |