Show Hamamatsu Avalanche Photo Diode 1415016257 - Archived data from Fri, 05. February 2021 11:28:27 CET
This is all the information about APD 1415016257. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1415016257 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | D05 |
Break-through voltage: | 418 V |
Voltage for Gain 100 (T=+25°C): | 388.9 V |
Dark current: | 5.5 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 310 |
Position in Box: | 22 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 408 |
Position in grid: | 16 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | 27. Oct 2017 |
Return for assembly: | none |
Irradiation: | |
Date: | 25. Oct 2017 |
Dose used: | 45 Gy |
Temperature: | 20 °C |
Position: | 4 |
Bias voltage: | 388.9 V (connected) |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 389.6312666 V T = -25 °C: 353.1572517 V |
Voltage for Gain 150: | T = +20 °C: 397.5431182 V T = -25 °C: 360.7863128 V |
Voltage for Gain 200: | T = +20 °C: 401.9164291 V T = -25 °C: 365.0221378 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.668796095 V-1 T = -25 °C: 4.677455452 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.234991012 V-1 T = -25 °C: 9.371959154 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.45427525 V-1 T = -25 °C: 14.74493536 V-1 |
Break-through voltage: | T = +20 °C: 417.451753 V T = -25 °C: 380.822232 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
11. Jul 2022 14:23:35 CEST | oafedulidis | Assigned to capsule by script |
27. Aug 2021 10:29:49 CEST | oafedulidis | Updated box and position via API. |
05. Feb 2021 11:28:27 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:58:51 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:45:24 CEST | jreher | Updated APD location via API. |
21. Jul 2020 14:45:14 CEST | jreher | Updated box and position via API. |
19. Dec 2019 16:48:20 CET | spankonin | Updated APD batch assignment via API. |
19. Dec 2019 15:19:08 CET | jreher | Updated box and position via API. |
27. Oct 2017 10:38:33 CEST | markus.moritz | Entered shipped after irradiation date. |
26. Oct 2017 16:28:27 CEST | markus.moritz | Entered irradiation information. |
29. Sep 2017 14:22:21 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:29:47 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:40:56 CEST | Tobias | Imported from Hamamatsu datasheet. |