RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1415016225 - Archived data from Tue, 11. August 2020 17:26:11 CEST


This is all the information about APD 1415016225. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1415016225
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C09
Break-through voltage: 418 V
Voltage for Gain 100 (T=+25°C): 389.8 V
Dark current: 5.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 40
Position in Box: 18
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 407
Position in grid: 7
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: 26. Nov 2018
Return for assembly: none
   
Irradiation:  
Date: 22. Nov 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 23. Nov 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 390.9675185 V     T = -25 °C: 354.5703941 V
Voltage for Gain 150: T = +20 °C: 398.9385534 V     T = -25 °C: 362.1794843 V
Voltage for Gain 200: T = +20 °C: 403.3591024 V     T = -25 °C: 366.4514442 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.588943895 V-1     T = -25 °C: 4.691002609 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.614367813 V-1     T = -25 °C: 9.231009388 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.77630347 V-1     T = -25 °C: 15.98613852 V-1
Break-through voltage: T = +20 °C: 418.1729561 V     T = -25 °C: 381.5843452 V
   
Notes:


Version history

Time Author Change comment
15. Nov 2022 13:06:04 CET oafedulidis Assigned to capsule by script
30. Aug 2021 14:07:23 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:53:21 CET jreher Updated box and position via API.
03. Feb 2021 18:19:08 CET jreher Updated box and position via API.
11. Aug 2020 17:26:11 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:36:04 CET jreher Updated APD location via API.
25. Nov 2019 17:14:03 CET jreher Updated box and position via API.
04. Jul 2019 11:11:02 CEST jreher Updated APD location via API.
12. Jun 2019 16:48:23 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:33:19 CEST jreher Updated APD batch assignment via API.
26. Nov 2018 15:16:02 CET markus.moritz
29. Sep 2017 13:49:05 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:36 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:40:55 CEST Tobias Imported from Hamamatsu datasheet.