Show Hamamatsu Avalanche Photo Diode 1415016216 - Archived data from Tue, 11. August 2020 17:26:10 CEST
This is all the information about APD 1415016216. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1415016216 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | B12 |
Break-through voltage: | 421 V |
Voltage for Gain 100 (T=+25°C): | 392.8 V |
Dark current: | 6.9 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 40 |
Position in Box: | 11 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 407 |
Position in grid: | 0 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | 26. Nov 2018 |
Return for assembly: | none |
Irradiation: | |
Date: | 22. Nov 2018 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 23. Nov 2018 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 392.8965494 V T = -25 °C: 356.3730864 V |
Voltage for Gain 150: | T = +20 °C: 400.8578832 V T = -25 °C: 364.0379302 V |
Voltage for Gain 200: | T = +20 °C: 405.3099471 V T = -25 °C: 368.3657605 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.394611133 V-1 T = -25 °C: 4.706783564 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.681015422 V-1 T = -25 °C: 8.851882446 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 13.28378172 V-1 T = -25 °C: 15.92907074 V-1 |
Break-through voltage: | T = +20 °C: 420.7635823 V T = -25 °C: 384.0637867 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 10:53:20 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:19:07 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:26:10 CEST | jreher | Updated APD characteristics via API. |
27. Nov 2019 19:36:03 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:14:03 CET | jreher | Updated box and position via API. |
04. Jul 2019 11:11:02 CEST | jreher | Updated APD location via API. |
12. Jun 2019 16:48:23 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 16:33:19 CEST | jreher | Updated APD batch assignment via API. |
26. Nov 2018 15:21:19 CET | markus.moritz | |
29. Sep 2017 13:49:05 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:29:36 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:40:54 CEST | Tobias | Imported from Hamamatsu datasheet. |