Show Hamamatsu Avalanche Photo Diode 1415016212 - Archived data from Tue, 11. August 2020 17:25:57 CEST
This is all the information about APD 1415016212. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1415016212 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | D12 |
Break-through voltage: | 424 V |
Voltage for Gain 100 (T=+25°C): | 395.3 V |
Dark current: | 7.1 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 38 |
Position in Box: | 48 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 406 |
Position in grid: | 16 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | 03. Jan 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 29. Nov 2018 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 30. Nov 2018 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 395.8328462 V T = -25 °C: 359.1029772 V |
Voltage for Gain 150: | T = +20 °C: 403.760769 V T = -25 °C: 366.8170799 V |
Voltage for Gain 200: | T = +20 °C: 408.195142 V T = -25 °C: 371.168327 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.605770337 V-1 T = -25 °C: 4.420169844 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.316132351 V-1 T = -25 °C: 9.442313014 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.0172167 V-1 T = -25 °C: 15.57377347 V-1 |
Break-through voltage: | T = +20 °C: 423.3920261 V T = -25 °C: 386.8099412 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 10:53:09 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:18:54 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:25:57 CEST | jreher | Updated APD characteristics via API. |
27. Nov 2019 19:35:44 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:13:56 CET | jreher | Updated box and position via API. |
04. Jul 2019 11:10:48 CEST | jreher | Updated APD location via API. |
12. Jun 2019 16:48:17 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 16:33:13 CEST | jreher | Updated APD batch assignment via API. |
03. Jan 2019 15:10:50 CET | markus.moritz | Entered shipped after irradiation date. |
03. Dec 2018 14:46:18 CET | markus.moritz | |
29. Sep 2017 12:27:36 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:29:35 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:40:54 CEST | Tobias | Imported from Hamamatsu datasheet. |