Show Hamamatsu Avalanche Photo Diode 1415016208 - Archived data from Fri, 05. February 2021 10:53:20 CET
This is all the information about APD 1415016208. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1415016208 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | F11 |
Break-through voltage: | 421 V |
Voltage for Gain 100 (T=+25°C): | 392.3 V |
Dark current: | 5.8 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 40 |
Position in Box: | 8 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 406 |
Position in grid: | 12 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | 03. Jan 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 29. Nov 2018 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 30. Nov 2018 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 392.8533568 V T = -25 °C: 356.5508995 V |
Voltage for Gain 150: | T = +20 °C: 400.6725879 V T = -25 °C: 364.2018618 V |
Voltage for Gain 200: | T = +20 °C: 405.0543964 V T = -25 °C: 368.4697389 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.639874801 V-1 T = -25 °C: 4.608297494 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.068122421 V-1 T = -25 °C: 8.470562407 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.1051452 V-1 T = -25 °C: 16.03840363 V-1 |
Break-through voltage: | T = +20 °C: 420.8007179 V T = -25 °C: 384.2350303 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
15. Nov 2022 12:56:21 CET | oafedulidis | Assigned to capsule by script |
16. Dec 2021 13:40:38 CET | oafedulidis | Updated box and position via API. |
05. Feb 2021 10:53:20 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:19:07 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:26:09 CEST | jreher | Updated APD characteristics via API. |
27. Nov 2019 19:36:03 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:14:02 CET | jreher | Updated box and position via API. |
04. Jul 2019 11:11:01 CEST | jreher | Updated APD location via API. |
12. Jun 2019 16:48:23 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 16:33:18 CEST | jreher | Updated APD batch assignment via API. |
03. Jan 2019 15:10:50 CET | markus.moritz | Entered shipped after irradiation date. |
03. Dec 2018 14:47:48 CET | markus.moritz | |
29. Sep 2017 12:27:36 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:29:35 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:40:54 CEST | Tobias | Imported from Hamamatsu datasheet. |