RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1413016095 - Archived data from Wed, 03. February 2021 18:18:54 CET


This is all the information about APD 1413016095. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1413016095
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C03
Break-through voltage: 416 V
Voltage for Gain 100 (T=+25°C): 387.2 V
Dark current: 6.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 38
Position in Box: 45
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 402
Position in grid: 9
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: 03. Jan 2019
Return for assembly: none
   
Irradiation:  
Date: 05. Dec 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 10. Dec 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 387.6425332 V     T = -25 °C: 351.9561081 V
Voltage for Gain 150: T = +20 °C: 395.5483757 V     T = -25 °C: 359.5485386 V
Voltage for Gain 200: T = +20 °C: 399.9055159 V     T = -25 °C: 363.7801329 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.231238357 V-1     T = -25 °C: 4.805614622 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.183151948 V-1     T = -25 °C: 11.10380192 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.87415987 V-1     T = -25 °C: 13.88657402 V-1
Break-through voltage: T = +20 °C: 415.7409341 V     T = -25 °C: 378.484503 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:53:09 CET jreher Updated box and position via API.
03. Feb 2021 18:18:54 CET jreher Updated box and position via API.
11. Aug 2020 17:25:57 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:35:44 CET jreher Updated APD location via API.
25. Nov 2019 17:13:55 CET jreher Updated box and position via API.
04. Jul 2019 11:10:48 CEST jreher Updated APD location via API.
12. Jun 2019 16:48:17 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:33:13 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 12:44:57 CET markus.moritz
29. Sep 2017 13:38:09 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:32 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:39:48 CEST Tobias Imported from Hamamatsu datasheet.