RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1413016091 - Archived data from Wed, 03. February 2021 18:18:54 CET


This is all the information about APD 1413016091. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1413016091
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E10
Break-through voltage: 419 V
Voltage for Gain 100 (T=+25°C): 390.6 V
Dark current: 5.2 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 38
Position in Box: 42
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 402
Position in grid: 6
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: 03. Jan 2019
Return for assembly: none
   
Irradiation:  
Date: 05. Dec 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 10. Dec 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 391.10157 V     T = -25 °C: 354.878721 V
Voltage for Gain 150: T = +20 °C: 399.0786107 V     T = -25 °C: 362.5155937 V
Voltage for Gain 200: T = +20 °C: 403.4975784 V     T = -25 °C: 366.8210418 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.52557156 V-1     T = -25 °C: 4.724591155 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.409740595 V-1     T = -25 °C: 8.91186663 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.82145668 V-1     T = -25 °C: 14.02393311 V-1
Break-through voltage: T = +20 °C: 418.7510283 V     T = -25 °C: 382.0686295 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:53:09 CET jreher Updated box and position via API.
03. Feb 2021 18:18:54 CET jreher Updated box and position via API.
11. Aug 2020 17:25:56 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:35:44 CET jreher Updated APD location via API.
25. Nov 2019 17:13:55 CET jreher Updated box and position via API.
04. Jul 2019 11:10:48 CEST jreher Updated APD location via API.
12. Jun 2019 16:48:16 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:33:12 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 12:44:13 CET markus.moritz
29. Sep 2017 13:38:09 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:32 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:39:48 CEST Tobias Imported from Hamamatsu datasheet.