Show Hamamatsu Avalanche Photo Diode 1413016076 - Archived data from Fri, 05. February 2021 10:53:28 CET
This is all the information about APD 1413016076. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1413016076 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | A10 |
Break-through voltage: | 416 V |
Voltage for Gain 100 (T=+25°C): | 390.2 V |
Dark current: | 6.6 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 41 |
Position in Box: | 3 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 401 |
Position in grid: | 12 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | 03. Jan 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 29. Nov 2018 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 30. Nov 2018 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 389.3341007 V T = -25 °C: 353.0841761 V |
Voltage for Gain 150: | T = +20 °C: 397.265051 V T = -25 °C: 360.6651717 V |
Voltage for Gain 200: | T = +20 °C: 401.6701539 V T = -25 °C: 364.9307369 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.33098458 V-1 T = -25 °C: 4.642581242 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.106772763 V-1 T = -25 °C: 9.110142063 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 13.90972012 V-1 T = -25 °C: 15.54904355 V-1 |
Break-through voltage: | T = +20 °C: 414.7130275 V T = -25 °C: 379.196824 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
26. Oct 2021 10:45:51 CEST | oafedulidis | Assigned to capsule by script |
17. May 2021 09:15:52 CEST | oafedulidis | Updated box and position via API. |
05. Feb 2021 10:53:28 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:19:14 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:26:18 CEST | jreher | Updated APD characteristics via API. |
27. Nov 2019 19:36:14 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:14:07 CET | jreher | Updated box and position via API. |
04. Jul 2019 11:11:09 CEST | jreher | Updated APD location via API. |
12. Jun 2019 16:48:26 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 16:33:22 CEST | jreher | Updated APD batch assignment via API. |
03. Jan 2019 15:07:38 CET | markus.moritz | Entered shipped after irradiation date. |
03. Dec 2018 14:26:31 CET | markus.moritz | |
29. Sep 2017 12:30:31 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:29:32 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:39:47 CEST | Tobias | Imported from Hamamatsu datasheet. |