Serial: 1413016061
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E13
Break-through voltage: 423 V
Voltage for Gain 100 (T=+25°C): 394.6 V
Dark current: 7.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 40
Position in Box: 38
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 400
Position in grid: 17
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: 03. Jan 2019
Return for assembly: none
   
Irradiation:  
Date: 05. Dec 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 10. Dec 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 395.0220173 V     T = -25 °C: 358.4221886 V
Voltage for Gain 150: T = +20 °C: 403.0102349 V     T = -25 °C: 366.1601276 V
Voltage for Gain 200: T = +20 °C: 407.4522984 V     T = -25 °C: 370.5240382 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.378777301 V-1     T = -25 °C: 4.772134436 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.121844529 V-1     T = -25 °C: 9.186326833 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.82186481 V-1     T = -25 °C: 13.88828314 V-1
Break-through voltage: T = +20 °C: 422.8272333 V     T = -25 °C: 386.2349534 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:53:24 CET jreher Updated box and position via API.
03. Feb 2021 18:19:10 CET jreher Updated box and position via API.
11. Aug 2020 17:26:16 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:36:05 CET jreher Updated APD location via API.
25. Nov 2019 17:14:05 CET jreher Updated box and position via API.
04. Jul 2019 11:11:04 CEST jreher Updated APD location via API.
12. Jun 2019 16:48:25 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:33:21 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 14:12:37 CET markus.moritz
29. Sep 2017 11:19:46 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:31 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:39:47 CEST Tobias Imported from Hamamatsu datasheet.