Subdetector specification:  
Serial: 1412015988
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G06
Break-through voltage: 420 V
Voltage for Gain 100 (T=+25°C): 391.1 V
Dark current: 5.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 41
Position in Box: 27
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 397
Position in grid: 11
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: 26. Nov 2018
Return for assembly: none
   
Irradiation:  
Date: 22. Nov 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 23. Nov 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 392.1005369 V     T = -25 °C: 355.8873996 V
Voltage for Gain 150: T = +20 °C: 400.0083239 V     T = -25 °C: 363.5120029 V
Voltage for Gain 200: T = +20 °C: 404.3676017 V     T = -25 °C: 367.8176299 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.44843161 V-1     T = -25 °C: 4.686821279 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.477789743 V-1     T = -25 °C: 8.89079959 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.02393839 V-1     T = -25 °C: 14.18362759 V-1
Break-through voltage: T = +20 °C: 419.7810651 V     T = -25 °C: 383.4212857 V
   
Notes:


Version history

Time Author Change comment
27. Sep 2021 16:13:09 CEST oafedulidis Assigned to capsule by script
17. May 2021 09:17:54 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:53:30 CET jreher Updated box and position via API.
03. Feb 2021 18:19:17 CET jreher Updated box and position via API.
11. Aug 2020 17:26:23 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:36:16 CET jreher Updated APD location via API.
25. Nov 2019 17:14:10 CET jreher Updated box and position via API.
04. Jul 2019 11:11:11 CEST jreher Updated APD location via API.
12. Jun 2019 16:48:29 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:33:25 CEST jreher Updated APD batch assignment via API.
26. Nov 2018 15:35:59 CET markus.moritz
29. Sep 2017 13:50:06 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:30 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:39:45 CEST Tobias Imported from Hamamatsu datasheet.