Show Hamamatsu Avalanche Photo Diode 1412015953 - Archived data from Tue, 11. August 2020 17:25:55 CEST
This is all the information about APD 1412015953. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1412015953 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | C07 |
Break-through voltage: | 422 V |
Voltage for Gain 100 (T=+25°C): | 392.7 V |
Dark current: | 8.7 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 38 |
Position in Box: | 32 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 395 |
Position in grid: | 16 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | 16. Jan 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 28. Nov 2018 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 30. Nov 2018 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 393.7511271 V T = -25 °C: 357.1445424 V |
Voltage for Gain 150: | T = +20 °C: 401.6610311 V T = -25 °C: 364.8190973 V |
Voltage for Gain 200: | T = +20 °C: 406.0576865 V T = -25 °C: 369.1405491 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.407279641 V-1 T = -25 °C: 4.701421141 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.070687489 V-1 T = -25 °C: 8.790240191 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.35727994 V-1 T = -25 °C: 15.65135688 V-1 |
Break-through voltage: | T = +20 °C: 421.2799215 V T = -25 °C: 384.4736364 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 10:53:07 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:18:53 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:25:55 CEST | jreher | Updated APD characteristics via API. |
27. Nov 2019 19:35:43 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:13:55 CET | jreher | Updated box and position via API. |
04. Jul 2019 11:10:47 CEST | jreher | Updated APD location via API. |
12. Jun 2019 16:48:15 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 16:33:11 CEST | jreher | Updated APD batch assignment via API. |
18. Jan 2019 14:32:36 CET | markus.moritz | Entered shipped after irradiation date. |
03. Dec 2018 12:15:17 CET | markus.moritz | |
29. Sep 2017 11:19:07 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:29:28 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:39:44 CEST | Tobias | Imported from Hamamatsu datasheet. |