RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1411015933 - Archived data from Wed, 07. October 2020 12:16:03 CEST


This is all the information about APD 1411015933. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1411015933
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 1908020875/1411015933
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: red
   
Manufacturer information:  
Wafer position: F03
Break-through voltage: 413 V
Voltage for Gain 100 (T=+25°C): 385.1 V
Dark current: 3.5 nA
   
Screening Logistics:  
Available: No
Storage Box: 31
Position in Box: 49
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 395
Position in grid: 8
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: 16. Jan 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Nov 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 30. Nov 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 386.3520448 V     T = -25 °C: 350.4384752 V
Voltage for Gain 150: T = +20 °C: 394.2610549 V     T = -25 °C: 357.9447821 V
Voltage for Gain 200: T = +20 °C: 398.6265544 V     T = -25 °C: 362.2255521 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.257116977 V-1     T = -25 °C: 4.823356782 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.570097701 V-1     T = -25 °C: 9.14812275 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.18057152 V-1     T = -25 °C: 16.87992212 V-1
Break-through voltage: T = +20 °C: 412.1043953 V     T = -25 °C: 377.2308504 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:51:54 CET jreher Updated box and position via API.
03. Feb 2021 18:18:00 CET jreher Updated box and position via API.
07. Oct 2020 12:16:03 CEST jreher Assigned to capsule by script
17. Aug 2020 15:53:04 CEST jreher Updated box and position via API.
11. Aug 2020 17:24:48 CEST jreher Updated APD characteristics via API.
28. Nov 2019 12:22:05 CET jreher Updated APD location via API.
25. Nov 2019 17:13:21 CET jreher Updated box and position via API.
13. Jun 2019 11:28:35 CEST jreher Updated APD location via API.
12. Jun 2019 16:47:45 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:32:40 CEST jreher Updated APD batch assignment via API.
18. Jan 2019 14:32:36 CET markus.moritz Entered shipped after irradiation date.
03. Dec 2018 12:43:28 CET markus.moritz
03. Dec 2018 12:24:32 CET markus.moritz
29. Sep 2017 11:19:06 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:28 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:39:44 CEST Tobias Imported from Hamamatsu datasheet.