Show Hamamatsu Avalanche Photo Diode 1411015929 - Archived data from Fri, 27. August 2021 10:31:12 CEST
This is all the information about APD 1411015929. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1411015929 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | C03 |
Break-through voltage: | 415 V |
Voltage for Gain 100 (T=+25°C): | 387.3 V |
Dark current: | 6.8 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 31 |
Position in Box: | 45 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 395 |
Position in grid: | 4 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | 16. Jan 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 28. Nov 2018 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 30. Nov 2018 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 387.6426968 V T = -25 °C: 351.5137615 V |
Voltage for Gain 150: | T = +20 °C: 395.5754589 V T = -25 °C: 359.0557813 V |
Voltage for Gain 200: | T = +20 °C: 400.0073079 V T = -25 °C: 363.3044599 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.574034811 V-1 T = -25 °C: 4.532605098 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.121174698 V-1 T = -25 °C: 8.900099845 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 13.74963059 V-1 T = -25 °C: 15.1742299 V-1 |
Break-through voltage: | T = +20 °C: 414.7415954 V T = -25 °C: 378.4127344 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
16. Nov 2021 10:41:36 CET | oafedulidis | Assigned to capsule by script |
27. Aug 2021 10:31:12 CEST | oafedulidis | Updated box and position via API. |
05. Feb 2021 10:51:54 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:17:59 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:24:47 CEST | jreher | Updated APD characteristics via API. |
28. Nov 2019 12:22:05 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:13:20 CET | jreher | Updated box and position via API. |
13. Jun 2019 11:28:35 CEST | jreher | Updated APD location via API. |
12. Jun 2019 16:47:45 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 16:32:40 CEST | jreher | Updated APD batch assignment via API. |
18. Jan 2019 14:32:35 CET | markus.moritz | Entered shipped after irradiation date. |
03. Dec 2018 12:29:51 CET | markus.moritz | |
29. Sep 2017 11:19:06 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:29:28 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:39:44 CEST | Tobias | Imported from Hamamatsu datasheet. |