RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0617005338 - Archived data from Tue, 11. August 2020 17:27:05 CEST


This is all the information about APD 0617005338. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0617005338
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F14
Break-through voltage: 453 V
Voltage for Gain 100 (T=+25°C): 425.5 V
Dark current: 15.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 45
Position in Box: 36
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 24. Jul 2018
Sent for analysis after irradiation: 21. Aug 2018
Return for assembly: none
   
Irradiation:  
Date: 16. Aug 2018
Dose used: 30 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Aug 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 425.3811276 V     T = -25 °C: 388.68667 V
Voltage for Gain 150: T = +20 °C: 433.2377938 V     T = -25 °C: 396.5418127 V
Voltage for Gain 200: T = +20 °C: 437.602762 V     T = -25 °C: 400.9079662 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.670900884 V-1     T = -25 °C: 4.561745984 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.11242167 V-1     T = -25 °C: 8.869688794 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.91659934 V-1     T = -25 °C: 15.09865971 V-1
Break-through voltage: T = +20 °C: 439.9888969 V     T = -25 °C: 414.987346 V
   
Notes: foam


Version history

Time Author Change comment
05. Feb 2021 10:54:00 CET jreher Updated box and position via API.
03. Feb 2021 18:19:48 CET jreher Updated box and position via API.
07. Oct 2020 15:46:07 CEST jreher Updated APD location via API.
11. Aug 2020 17:27:05 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:37:01 CET jreher Updated APD location via API.
25. Nov 2019 17:14:30 CET jreher Updated box and position via API.
04. Jul 2019 11:11:45 CEST jreher Updated APD location via API.
12. Jun 2019 16:48:42 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:33:38 CEST jreher Updated APD batch assignment via API.
21. Aug 2018 11:15:08 CEST markus.moritz
28. Apr 2014 15:40:36 CEST Tobias Imported from Hamamatsu datasheet.