RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1410015845 - Archived data from Wed, 03. February 2021 18:18:42 CET


This is all the information about APD 1410015845. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1410015845
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F11
Break-through voltage: 428 V
Voltage for Gain 100 (T=+25°C): 399.7 V
Dark current: 7.2 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 37
Position in Box: 7
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 391
Position in grid: 8
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: 03. Jan 2019
Return for assembly: none
   
Irradiation:  
Date: 05. Dec 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 10. Dec 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 399.9928624 V     T = -25 °C: 363.2881506 V
Voltage for Gain 150: T = +20 °C: 407.9152231 V     T = -25 °C: 371.0909244 V
Voltage for Gain 200: T = +20 °C: 412.3201501 V     T = -25 °C: 375.4384339 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.489339321 V-1     T = -25 °C: 4.483478683 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.713391315 V-1     T = -25 °C: 8.684141614 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.8500461 V-1     T = -25 °C: 14.77881402 V-1
Break-through voltage: T = +20 °C: 427.9041577 V     T = -25 °C: 391.0924364 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:52:47 CET jreher Updated box and position via API.
03. Feb 2021 18:18:42 CET jreher Updated box and position via API.
11. Aug 2020 17:25:39 CEST jreher Updated APD characteristics via API.
28. Nov 2019 12:23:10 CET jreher Updated APD location via API.
25. Nov 2019 17:13:47 CET jreher Updated box and position via API.
13. Jun 2019 11:29:54 CEST jreher Updated APD location via API.
12. Jun 2019 16:48:09 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:33:04 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 12:59:52 CET markus.moritz
29. Sep 2017 12:25:44 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:25 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:39:42 CEST Tobias Imported from Hamamatsu datasheet.