Show Hamamatsu Avalanche Photo Diode 1410015812 - Archived data from Tue, 11. August 2020 17:25:50 CEST
This is all the information about APD 1410015812. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1410015812 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | D06 |
Break-through voltage: | 424 V |
Voltage for Gain 100 (T=+25°C): | 395.7 V |
Dark current: | 7.1 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 38 |
Position in Box: | 11 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 389 |
Position in grid: | 16 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | 16. Jan 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 29. Nov 2018 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 30. Nov 2018 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 396.3463631 V T = -25 °C: 359.6211354 V |
Voltage for Gain 150: | T = +20 °C: 404.404424 V T = -25 °C: 367.4755799 V |
Voltage for Gain 200: | T = +20 °C: 408.8617212 V T = -25 °C: 371.7267873 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.747343608 V-1 T = -25 °C: 4.953831275 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.340919139 V-1 T = -25 °C: 7.610401516 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.44408136 V-1 T = -25 °C: 14.44531552 V-1 |
Break-through voltage: | T = +20 °C: 424.1794148 V T = -25 °C: 387.3261774 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 10:53:05 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:18:50 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:25:50 CEST | jreher | Updated APD characteristics via API. |
27. Nov 2019 19:35:41 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:13:53 CET | jreher | Updated box and position via API. |
04. Jul 2019 11:10:45 CEST | jreher | Updated APD location via API. |
12. Jun 2019 16:48:13 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 16:33:09 CEST | jreher | Updated APD batch assignment via API. |
18. Jan 2019 14:31:37 CET | markus.moritz | Entered shipped after irradiation date. |
03. Dec 2018 14:29:39 CET | markus.moritz | |
29. Sep 2017 11:20:23 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:29:46 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:39:41 CEST | Tobias | Imported from Hamamatsu datasheet. |