Show Hamamatsu Avalanche Photo Diode 1410015795 - Archived data from Tue, 11. August 2020 17:24:45 CEST
This is all the information about APD 1410015795. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1410015795 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | D07 |
Break-through voltage: | 423 V |
Voltage for Gain 100 (T=+25°C): | 394.3 V |
Dark current: | 6.3 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 31 |
Position in Box: | 35 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 389 |
Position in grid: | 0 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | 16. Jan 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 29. Nov 2018 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 30. Nov 2018 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 395.1596154 V T = -25 °C: 358.5832263 V |
Voltage for Gain 150: | T = +20 °C: 403.1104198 V T = -25 °C: 366.1820098 V |
Voltage for Gain 200: | T = +20 °C: 407.5077695 V T = -25 °C: 370.5222634 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.439466507 V-1 T = -25 °C: 4.316677519 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.358680255 V-1 T = -25 °C: 8.65680395 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.61851737 V-1 T = -25 °C: 15.41138888 V-1 |
Break-through voltage: | T = +20 °C: 422.871972 V T = -25 °C: 385.9638191 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 10:51:53 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:17:58 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:24:45 CEST | jreher | Updated APD characteristics via API. |
28. Nov 2019 12:22:04 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:13:20 CET | jreher | Updated box and position via API. |
13. Jun 2019 11:28:34 CEST | jreher | Updated APD location via API. |
12. Jun 2019 16:47:44 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 16:32:39 CEST | jreher | Updated APD batch assignment via API. |
18. Jan 2019 14:31:36 CET | markus.moritz | Entered shipped after irradiation date. |
03. Dec 2018 14:25:21 CET | markus.moritz | |
29. Sep 2017 11:20:23 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:29:45 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:39:40 CEST | Tobias | Imported from Hamamatsu datasheet. |