Show Hamamatsu Avalanche Photo Diode 1409015766 - Archived data from Tue, 11. August 2020 17:24:45 CEST
This is all the information about APD 1409015766. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1409015766 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | B08 |
Break-through voltage: | 421 V |
Voltage for Gain 100 (T=+25°C): | 393.5 V |
Dark current: | 6.4 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 31 |
Position in Box: | 34 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 387 |
Position in grid: | 19 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | 16. Jan 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 28. Nov 2018 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 30. Nov 2018 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 393.2875573 V T = -25 °C: 356.8805869 V |
Voltage for Gain 150: | T = +20 °C: 401.2247343 V T = -25 °C: 364.568423 V |
Voltage for Gain 200: | T = +20 °C: 405.6705463 V T = -25 °C: 368.8727411 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.390632183 V-1 T = -25 °C: 4.731800439 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.867495183 V-1 T = -25 °C: 9.416125391 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 15.20844567 V-1 T = -25 °C: 14.66857603 V-1 |
Break-through voltage: | T = +20 °C: 421.0132718 V T = -25 °C: 384.4815603 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 10:51:52 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:17:58 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:24:45 CEST | jreher | Updated APD characteristics via API. |
28. Nov 2019 12:22:04 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:13:20 CET | jreher | Updated box and position via API. |
13. Jun 2019 11:28:34 CEST | jreher | Updated APD location via API. |
12. Jun 2019 16:47:44 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 16:32:39 CEST | jreher | Updated APD batch assignment via API. |
18. Jan 2019 14:33:55 CET | markus.moritz | Entered shipped after irradiation date. |
03. Dec 2018 12:14:22 CET | markus.moritz | |
29. Sep 2017 12:04:26 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:29:23 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:32:31 CEST | Tobias | Imported from Hamamatsu datasheet. |