RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1409015756 - Archived data from Tue, 11. August 2020 17:24:32 CEST


This is all the information about APD 1409015756. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1409015756
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: H07
Break-through voltage: 414 V
Voltage for Gain 100 (T=+25°C): 386.5 V
Dark current: 4.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 30
Position in Box: 17
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 387
Position in grid: 12
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: 16. Jan 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Nov 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 30. Nov 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 387.9849344 V     T = -25 °C: 352.0885532 V
Voltage for Gain 150: T = +20 °C: 395.9597607 V     T = -25 °C: 359.6828665 V
Voltage for Gain 200: T = +20 °C: 400.382035 V     T = -25 °C: 363.9440802 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.488506946 V-1     T = -25 °C: 4.582252466 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.205562839 V-1     T = -25 °C: 9.559603342 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.59346336 V-1     T = -25 °C: 15.2859721 V-1
Break-through voltage: T = +20 °C: 411.3090648 V     T = -25 °C: 377.3050299 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:51:42 CET jreher Updated box and position via API.
03. Feb 2021 18:17:48 CET jreher Updated box and position via API.
11. Aug 2020 17:24:32 CEST jreher Updated APD characteristics via API.
28. Nov 2019 12:21:51 CET jreher Updated APD location via API.
25. Nov 2019 17:13:14 CET jreher Updated box and position via API.
13. Jun 2019 11:19:38 CEST jreher Updated APD location via API.
13. Jun 2019 11:19:01 CEST jreher Updated APD location via API.
12. Jun 2019 16:47:37 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:32:32 CEST jreher Updated APD batch assignment via API.
18. Jan 2019 14:33:55 CET markus.moritz Entered shipped after irradiation date.
03. Dec 2018 12:42:02 CET markus.moritz
29. Sep 2017 12:04:26 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:23 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:32:31 CEST Tobias Imported from Hamamatsu datasheet.