Show Hamamatsu Avalanche Photo Diode 1409015705 - Archived data from Tue, 11. August 2020 17:25:04 CEST
This is all the information about APD 1409015705. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1409015705 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | D03 |
Break-through voltage: | 420 V |
Voltage for Gain 100 (T=+25°C): | 391.8 V |
Dark current: | 5.9 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 33 |
Position in Box: | 29 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 385 |
Position in grid: | 7 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | 26. Nov 2018 |
Return for assembly: | none |
Irradiation: | |
Date: | 22. Nov 2018 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 23. Nov 2018 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 392.2237505 V T = -25 °C: 355.6799112 V |
Voltage for Gain 150: | T = +20 °C: 400.1748706 V T = -25 °C: 363.3543039 V |
Voltage for Gain 200: | T = +20 °C: 404.5978914 V T = -25 °C: 367.6890474 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.360133424 V-1 T = -25 °C: 4.740757042 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.108337957 V-1 T = -25 °C: 9.203657236 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 13.91772715 V-1 T = -25 °C: 13.97070885 V-1 |
Break-through voltage: | T = +20 °C: 420.0369273 V T = -25 °C: 383.2651247 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 10:52:07 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:18:13 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:25:04 CEST | jreher | Updated APD characteristics via API. |
28. Nov 2019 12:22:27 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:13:29 CET | jreher | Updated box and position via API. |
13. Jun 2019 11:29:02 CEST | jreher | Updated APD location via API. |
12. Jun 2019 16:47:52 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 16:32:48 CEST | jreher | Updated APD batch assignment via API. |
26. Nov 2018 13:53:54 CET | markus.moritz | |
29. Sep 2017 13:36:52 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:29:21 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:32:29 CEST | Tobias | Imported from Hamamatsu datasheet. |