RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1408015684 - Archived data from Tue, 11. August 2020 17:25:46 CEST


This is all the information about APD 1408015684. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1408015684
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F05
Break-through voltage: 419 V
Voltage for Gain 100 (T=+25°C): 390 V
Dark current: 4.4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 37
Position in Box: 40
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 384
Position in grid: 6
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: 16. Jan 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Nov 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 30. Nov 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 390.5798169 V     T = -25 °C: 354.1429212 V
Voltage for Gain 150: T = +20 °C: 398.4969402 V     T = -25 °C: 361.7393618 V
Voltage for Gain 200: T = +20 °C: 402.8904568 V     T = -25 °C: 366.0932358 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.174604044 V-1     T = -25 °C: 4.733949835 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.38432005 V-1     T = -25 °C: 9.433674564 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.29364046 V-1     T = -25 °C: 14.27908911 V-1
Break-through voltage: T = +20 °C: 418.8025974 V     T = -25 °C: 382.2168873 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:52:56 CET jreher Updated box and position via API.
03. Feb 2021 18:18:46 CET jreher Updated box and position via API.
11. Aug 2020 17:25:46 CEST jreher Updated APD characteristics via API.
28. Nov 2019 12:23:13 CET jreher Updated APD location via API.
25. Nov 2019 17:13:50 CET jreher Updated box and position via API.
13. Jun 2019 11:29:57 CEST jreher Updated APD location via API.
12. Jun 2019 16:48:12 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:33:07 CEST jreher Updated APD batch assignment via API.
18. Jan 2019 14:44:58 CET markus.moritz
03. Dec 2018 13:36:14 CET markus.moritz
29. Sep 2017 14:07:20 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:21 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:32:29 CEST Tobias Imported from Hamamatsu datasheet.