Show Hamamatsu Avalanche Photo Diode 1408015684 - Archived data from Tue, 11. August 2020 17:25:46 CEST
This is all the information about APD 1408015684. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1408015684 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | F05 |
Break-through voltage: | 419 V |
Voltage for Gain 100 (T=+25°C): | 390 V |
Dark current: | 4.4 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 37 |
Position in Box: | 40 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 384 |
Position in grid: | 6 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | 16. Jan 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 28. Nov 2018 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 30. Nov 2018 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 390.5798169 V T = -25 °C: 354.1429212 V |
Voltage for Gain 150: | T = +20 °C: 398.4969402 V T = -25 °C: 361.7393618 V |
Voltage for Gain 200: | T = +20 °C: 402.8904568 V T = -25 °C: 366.0932358 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.174604044 V-1 T = -25 °C: 4.733949835 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.38432005 V-1 T = -25 °C: 9.433674564 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.29364046 V-1 T = -25 °C: 14.27908911 V-1 |
Break-through voltage: | T = +20 °C: 418.8025974 V T = -25 °C: 382.2168873 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 10:52:56 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:18:46 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:25:46 CEST | jreher | Updated APD characteristics via API. |
28. Nov 2019 12:23:13 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:13:50 CET | jreher | Updated box and position via API. |
13. Jun 2019 11:29:57 CEST | jreher | Updated APD location via API. |
12. Jun 2019 16:48:12 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 16:33:07 CEST | jreher | Updated APD batch assignment via API. |
18. Jan 2019 14:44:58 CET | markus.moritz | |
03. Dec 2018 13:36:14 CET | markus.moritz | |
29. Sep 2017 14:07:20 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:29:21 CEST | Tobias | Assigned to grid via information extracted from APD DB. |