RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1408015672 - Archived data from Wed, 16. June 2021 16:02:55 CEST


This is all the information about APD 1408015672. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1408015672
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G10
Break-through voltage: 423 V
Voltage for Gain 100 (T=+25°C): 394.1 V
Dark current: 5.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 306
Position in Box: 25
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 383
Position in grid: 14
Arrival for irradiation: 02. Nov 2017
Sent for analysis after irradiation: 10. Nov 2017
Return for assembly: none
   
Irradiation:  
Date: 08. Nov 2017
Dose used: 45 Gy
Temperature: 20 °C
Position: 3
Bias voltage: 394.1 V     (connected)
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 394.5622072 V     T = -25 °C: 358.1791629 V
Voltage for Gain 150: T = +20 °C: 402.4663138 V     T = -25 °C: 365.8757334 V
Voltage for Gain 200: T = +20 °C: 406.840025 V     T = -25 °C: 370.1994909 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.372818782 V-1     T = -25 °C: 4.647092563 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.498074424 V-1     T = -25 °C: 9.185469022 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.65465264 V-1     T = -25 °C: 14.21441058 V-1
Break-through voltage: T = +20 °C: 421.712382 V     T = -25 °C: 386.2072667 V
   
Notes:


Version history

Time Author Change comment
19. Nov 2021 13:06:21 CET oafedulidis Assigned to capsule by script
16. Jun 2021 16:02:55 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:59:19 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:51:58 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:27:48 CET jreher Updated box and position via API.
11. Aug 2020 17:58:12 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:44:26 CEST jreher Updated APD location via API.
21. Jul 2020 14:44:16 CEST jreher Updated box and position via API.
19. Dec 2019 16:35:05 CET spankonin Updated APD batch assignment via API.
19. Dec 2019 15:18:37 CET jreher Updated box and position via API.
10. Nov 2017 09:38:50 CET markus.moritz Entered shipped after irradiation date.
09. Nov 2017 15:01:21 CET markus.moritz Entered irradiation information.
02. Nov 2017 15:18:31 CET markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:20 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:32:28 CEST Tobias Imported from Hamamatsu datasheet.