Show Hamamatsu Avalanche Photo Diode 1408015665 - Archived data from Tue, 11. August 2020 17:58:11 CEST
This is all the information about APD 1408015665. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1408015665 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | B11 |
Break-through voltage: | 425 V |
Voltage for Gain 100 (T=+25°C): | 396.1 V |
Dark current: | 5.8 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 306 |
Position in Box: | 20 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 383 |
Position in grid: | 7 |
Arrival for irradiation: | 02. Nov 2017 |
Sent for analysis after irradiation: | 10. Nov 2017 |
Return for assembly: | none |
Irradiation: | |
Date: | 08. Nov 2017 |
Dose used: | 45 Gy |
Temperature: | 20 °C |
Position: | 3 |
Bias voltage: | 396.1 V (connected) |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 396.3828335 V T = -25 °C: 360.1695548 V |
Voltage for Gain 150: | T = +20 °C: 404.280587 V T = -25 °C: 367.8352918 V |
Voltage for Gain 200: | T = +20 °C: 408.6704034 V T = -25 °C: 372.1208629 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.445466659 V-1 T = -25 °C: 4.669648709 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.684332527 V-1 T = -25 °C: 9.313051897 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 15.11159756 V-1 T = -25 °C: 14.53914127 V-1 |
Break-through voltage: | T = +20 °C: 424.5041099 V T = -25 °C: 388.0656411 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:27:47 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:58:11 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:44:25 CEST | jreher | Updated APD location via API. |
21. Jul 2020 14:44:15 CEST | jreher | Updated box and position via API. |
19. Dec 2019 16:33:49 CET | spankonin | Updated APD batch assignment via API. |
19. Dec 2019 15:18:37 CET | jreher | Updated box and position via API. |
10. Nov 2017 09:38:50 CET | markus.moritz | Entered shipped after irradiation date. |
09. Nov 2017 15:01:21 CET | markus.moritz | Entered irradiation information. |
02. Nov 2017 15:18:31 CET | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:29:20 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:32:28 CEST | Tobias | Imported from Hamamatsu datasheet. |