Subdetector specification:  
Serial: 1407015599
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum, Box 30
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D11
Break-through voltage: 421 V
Voltage for Gain 100 (T=+25°C): 391.9 V
Dark current: 6.9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 30
Position in Box: 1
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 380
Position in grid: 0
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: 16. Jan 2019
Return for assembly: none
   
Irradiation:  
Date: 29. Nov 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 30. Nov 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 150: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 200: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 100: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 150: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 200: T = +20 °C: none     T = -25 °C: none
Break-through voltage: T = +20 °C: none     T = -25 °C: none
   
Notes:


Version history

Time Author Change comment
16. Nov 2022 10:02:12 CET oafedulidis Assigned to capsule by script
30. Aug 2021 14:07:39 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:51:40 CET jreher Updated box and position via API.
03. Feb 2021 18:17:46 CET jreher Updated box and position via API.
11. Aug 2020 17:24:30 CEST jreher Updated APD characteristics via API.
28. Nov 2019 12:21:50 CET jreher Updated APD location via API.
25. Nov 2019 17:13:12 CET jreher Updated box and position via API.
13. Jun 2019 11:19:37 CEST jreher Updated APD location via API.
13. Jun 2019 11:19:00 CEST jreher Updated APD location via API.
12. Jun 2019 16:47:36 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:32:31 CEST jreher Updated APD batch assignment via API.
18. Jan 2019 14:29:02 CET markus.moritz
03. Dec 2018 14:22:39 CET markus.moritz
29. Sep 2017 12:04:51 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:18 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:32:26 CEST Tobias Imported from Hamamatsu datasheet.