RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1407015587


This is all the information about APD 1407015587. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1407015587
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2408026502/1407015587
Unit: #2833 (barcode 1309024940)
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: red
   
Manufacturer information:  
Wafer position: E09
Break-through voltage: 417 V
Voltage for Gain 100 (T=+25°C): 388.2 V
Dark current: 6.2 nA
   
Screening Logistics:  
Available: No
Storage Box: 348
Position in Box: 8
EP1 batch: none
EP1 batch after irradiation: 10527
   
Shipment:  
Grid number: 379
Position in grid: 8
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 388.7776181 V     T = -25 °C: 352.4466633 V
Voltage for Gain 150: T = +20 °C: 396.6635673 V     T = -25 °C: 359.9704285 V
Voltage for Gain 200: T = +20 °C: 401.0455493 V     T = -25 °C: 364.1945367 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.66874823 V-1     T = -25 °C: 4.674653266 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.277407649 V-1     T = -25 °C: 9.335611907 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.34811617 V-1     T = -25 °C: 14.6034826 V-1
Break-through voltage: T = +20 °C: 416.6901221 V     T = -25 °C: 379.9383975 V
   
Notes:


Characteristics

Temperature Measurement Notes
No characteristics available!


Upload new characteristic...

Progression of the current during irradiation

Upload time Notes
No data available!


Upload new progression data...

Version history

Time Author Change comment
16. Nov 2021 09:31:08 CET oafedulidis Assigned to capsule by script
16. Apr 2021 22:00:06 CEST jreher Updated APD characteristics via API.
15. Apr 2021 17:00:53 CEST jreher Updated box and position via API.
05. Feb 2021 11:32:54 CET jreher Updated box and position via API.
17. Aug 2020 13:54:52 CEST vwerner Updated APD batch assignment via API.
11. Aug 2020 17:54:35 CEST jreher Updated APD location via API.
01. Aug 2016 17:29:17 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:32:26 CEST Tobias Imported from Hamamatsu datasheet.