Show Hamamatsu Avalanche Photo Diode 1407015568 - Archived data from Fri, 05. February 2021 11:27:52 CET
This is all the information about APD 1407015568. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1407015568 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | A08 |
Break-through voltage: | 417 V |
Voltage for Gain 100 (T=+25°C): | 390.3 V |
Dark current: | 7.2 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 306 |
Position in Box: | 38 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 378 |
Position in grid: | 11 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | 27. Oct 2017 |
Return for assembly: | none |
Irradiation: | |
Date: | 25. Oct 2017 |
Dose used: | 45 Gy |
Temperature: | 20 °C |
Position: | 3 |
Bias voltage: | 390.3 V (connected) |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 389.4725543 V T = -25 °C: 353.5415909 V |
Voltage for Gain 150: | T = +20 °C: 397.4622545 V T = -25 °C: 361.1427065 V |
Voltage for Gain 200: | T = +20 °C: 401.8901501 V T = -25 °C: 365.4270625 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.3590092 V-1 T = -25 °C: 4.59020178 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.417903154 V-1 T = -25 °C: 9.022578355 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.47623819 V-1 T = -25 °C: 15.91879081 V-1 |
Break-through voltage: | T = +20 °C: 416.1977829 V T = -25 °C: 379.9105591 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
16. Nov 2022 10:00:13 CET | oafedulidis | Assigned to capsule by script |
05. Feb 2021 11:27:52 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:58:15 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:44:27 CEST | jreher | Updated APD location via API. |
21. Jul 2020 14:44:17 CEST | jreher | Updated box and position via API. |
19. Dec 2019 16:35:06 CET | spankonin | Updated APD batch assignment via API. |
19. Dec 2019 15:18:38 CET | jreher | Updated box and position via API. |
27. Oct 2017 10:37:31 CEST | markus.moritz | Entered shipped after irradiation date. |
26. Oct 2017 16:30:41 CEST | markus.moritz | Entered irradiation information. |
29. Sep 2017 11:43:47 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:29:17 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:32:25 CEST | Tobias | Imported from Hamamatsu datasheet. |