Subdetector specification:  
Serial: 1406015518
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D02
Break-through voltage: 421 V
Voltage for Gain 100 (T=+25°C): 392.4 V
Dark current: 5.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 42
Position in Box: 18
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 376
Position in grid: 9
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: 26. Nov 2018
Return for assembly: none
   
Irradiation:  
Date: 22. Nov 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 23. Nov 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 392.874425 V     T = -25 °C: 356.5223857 V
Voltage for Gain 150: T = +20 °C: 400.8790692 V     T = -25 °C: 364.2111812 V
Voltage for Gain 200: T = +20 °C: 405.3261955 V     T = -25 °C: 368.5581748 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.444566183 V-1     T = -25 °C: 4.756127786 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.409439307 V-1     T = -25 °C: 9.229228011 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.0501962 V-1     T = -25 °C: 13.966866 V-1
Break-through voltage: T = +20 °C: 420.9776936 V     T = -25 °C: 384.3670111 V
   
Notes:


Version history

Time Author Change comment
10. Jun 2022 12:28:50 CEST oafedulidis Assigned to capsule by script
30. Aug 2021 14:08:13 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:53:37 CET jreher Updated box and position via API.
03. Feb 2021 18:19:24 CET jreher Updated box and position via API.
11. Aug 2020 17:26:31 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:36:26 CET jreher Updated APD location via API.
25. Nov 2019 17:14:15 CET jreher Updated box and position via API.
04. Jul 2019 11:11:19 CEST jreher Updated APD location via API.
12. Jun 2019 16:48:32 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:33:28 CEST jreher Updated APD batch assignment via API.
26. Nov 2018 14:33:41 CET markus.moritz
29. Sep 2017 13:35:59 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:15 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:32:24 CEST Tobias Imported from Hamamatsu datasheet.