Show Hamamatsu Avalanche Photo Diode 1406015517 - Archived data from Tue, 11. August 2020 17:26:30 CEST
This is all the information about APD 1406015517. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1406015517 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | D03 |
Break-through voltage: | 423 V |
Voltage for Gain 100 (T=+25°C): | 393.5 V |
Dark current: | 5.5 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 42 |
Position in Box: | 17 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 376 |
Position in grid: | 8 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | 26. Nov 2018 |
Return for assembly: | none |
Irradiation: | |
Date: | 22. Nov 2018 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 23. Nov 2018 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 393.8050206 V T = -25 °C: 357.4056933 V |
Voltage for Gain 150: | T = +20 °C: 401.7939702 V T = -25 °C: 365.1245074 V |
Voltage for Gain 200: | T = +20 °C: 406.2335594 V T = -25 °C: 369.480488 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.441838542 V-1 T = -25 °C: 4.773415442 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.491800457 V-1 T = -25 °C: 9.286142143 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.17682762 V-1 T = -25 °C: 14.03321225 V-1 |
Break-through voltage: | T = +20 °C: 422.1618238 V T = -25 °C: 385.6177198 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 10:53:37 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:19:24 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:26:30 CEST | jreher | Updated APD characteristics via API. |
27. Nov 2019 19:36:26 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:14:15 CET | jreher | Updated box and position via API. |
04. Jul 2019 11:11:19 CEST | jreher | Updated APD location via API. |
12. Jun 2019 16:48:32 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 16:33:28 CEST | jreher | Updated APD batch assignment via API. |
26. Nov 2018 14:34:26 CET | markus.moritz | |
29. Sep 2017 13:35:59 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:29:15 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:32:24 CEST | Tobias | Imported from Hamamatsu datasheet. |