RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1406015512 - Archived data from Wed, 03. February 2021 18:19:23 CET


This is all the information about APD 1406015512. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1406015512
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E14
Break-through voltage: 421 V
Voltage for Gain 100 (T=+25°C): 393 V
Dark current: 6.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 42
Position in Box: 12
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 376
Position in grid: 3
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: 26. Nov 2018
Return for assembly: none
   
Irradiation:  
Date: 22. Nov 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 23. Nov 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 393.17092 V     T = -25 °C: 356.8608481 V
Voltage for Gain 150: T = +20 °C: 401.0720805 V     T = -25 °C: 364.5372031 V
Voltage for Gain 200: T = +20 °C: 405.4745477 V     T = -25 °C: 368.8559404 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.385138617 V-1     T = -25 °C: 4.631433587 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.163565213 V-1     T = -25 °C: 8.902757828 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.83167159 V-1     T = -25 °C: 15.03887717 V-1
Break-through voltage: T = +20 °C: 420.4835534 V     T = -25 °C: 384.1738261 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:53:36 CET jreher Updated box and position via API.
03. Feb 2021 18:19:23 CET jreher Updated box and position via API.
11. Aug 2020 17:26:30 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:36:26 CET jreher Updated APD location via API.
25. Nov 2019 17:14:14 CET jreher Updated box and position via API.
04. Jul 2019 11:11:18 CEST jreher Updated APD location via API.
12. Jun 2019 16:48:32 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:33:28 CEST jreher Updated APD batch assignment via API.
26. Nov 2018 14:37:34 CET markus.moritz
29. Sep 2017 13:35:59 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:15 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:32:24 CEST Tobias Imported from Hamamatsu datasheet.