Show Hamamatsu Avalanche Photo Diode 1406015495 - Archived data from Wed, 07. October 2020 14:22:34 CEST
This is all the information about APD 1406015495. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1406015495 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | assigned to 1406015495/2809031539 |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | blue |
Manufacturer information: | |
Wafer position: | H10 |
Break-through voltage: | 417 V |
Voltage for Gain 100 (T=+25°C): | 390.6 V |
Dark current: | 4.7 nA |
Screening Logistics: | |
Available: | No |
Storage Box: | 36 |
Position in Box: | 23 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 375 |
Position in grid: | 6 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | 03. Jan 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 05. Dec 2018 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 10. Dec 2018 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 391.684765 V T = -25 °C: 355.3665949 V |
Voltage for Gain 150: | T = +20 °C: 399.6324246 V T = -25 °C: 363.0053566 V |
Voltage for Gain 200: | T = +20 °C: 403.997931 V T = -25 °C: 367.3056851 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.604152829 V-1 T = -25 °C: 4.640038241 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.367113386 V-1 T = -25 °C: 9.040538376 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 15.41584334 V-1 T = -25 °C: 14.48751098 V-1 |
Break-through voltage: | T = +20 °C: 413.6817259 V T = -25 °C: 381.6322577 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 10:52:41 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:18:36 CET | jreher | Updated box and position via API. |
07. Oct 2020 14:22:34 CEST | jreher | Assigned to capsule by script |
17. Aug 2020 15:53:52 CEST | jreher | Updated box and position via API. |
11. Aug 2020 17:25:32 CEST | jreher | Updated APD characteristics via API. |
28. Nov 2019 12:23:00 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:13:43 CET | jreher | Updated box and position via API. |
13. Jun 2019 11:29:43 CEST | jreher | Updated APD location via API. |
12. Jun 2019 16:48:06 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 16:33:01 CEST | jreher | Updated APD batch assignment via API. |
03. Jan 2019 12:13:42 CET | markus.moritz | |
29. Sep 2017 11:17:36 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:29:15 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:32:23 CEST | Tobias | Imported from Hamamatsu datasheet. |