Show Hamamatsu Avalanche Photo Diode 0617005301 - Archived data from Wed, 03. February 2021 18:19:32 CET
This is all the information about APD 0617005301. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 0617005301 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | In transit to Mainz |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | A10 |
Break-through voltage: | 456 V |
Voltage for Gain 100 (T=+25°C): | 428.1 V |
Dark current: | 15.6 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 43 |
Position in Box: | 18 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | none |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 428.7465702 V T = -25 °C: 391.7085458 V |
Voltage for Gain 150: | T = +20 °C: 436.6667266 V T = -25 °C: 399.5896346 V |
Voltage for Gain 200: | T = +20 °C: 438.800605 V T = -25 °C: 403.9690806 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.515705167 V-1 T = -25 °C: 4.532786951 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.697203208 V-1 T = -25 °C: 8.748327708 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 10.58749596 V-1 T = -25 °C: 14.86181378 V-1 |
Break-through voltage: | T = +20 °C: 440.0116342 V T = -25 °C: 415.0147393 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 10:53:45 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:19:32 CET | jreher | Updated box and position via API. |
07. Oct 2020 15:46:01 CEST | jreher | Updated APD location via API. |
11. Aug 2020 17:26:40 CEST | jreher | Updated APD characteristics via API. |
27. Nov 2019 19:36:37 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:14:20 CET | jreher | Updated box and position via API. |
04. Jul 2019 11:11:27 CEST | jreher | Updated APD location via API. |
12. Jun 2019 16:48:37 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 16:33:33 CEST | jreher | Updated APD batch assignment via API. |
28. Apr 2014 15:40:36 CEST | Tobias | Imported from Hamamatsu datasheet. |