Show Hamamatsu Avalanche Photo Diode 0617005297 - Archived data from Wed, 03. February 2021 18:19:33 CET
This is all the information about APD 0617005297. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 0617005297 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | In transit to Mainz |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | A09 |
Break-through voltage: | 455 V |
Voltage for Gain 100 (T=+25°C): | 427 V |
Dark current: | 14.9 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 43 |
Position in Box: | 32 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | none |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 427.6363088 V T = -25 °C: 390.836559 V |
Voltage for Gain 150: | T = +20 °C: 435.5560525 V T = -25 °C: 398.7450544 V |
Voltage for Gain 200: | T = +20 °C: 438.645253 V T = -25 °C: 403.1264042 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.52536845 V-1 T = -25 °C: 4.471819387 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.675566062 V-1 T = -25 °C: 8.589706911 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 11.80980423 V-1 T = -25 °C: 14.47740214 V-1 |
Break-through voltage: | T = +20 °C: 439.9766852 V T = -25 °C: 414.9877193 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 10:53:46 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:19:33 CET | jreher | Updated box and position via API. |
07. Oct 2020 15:46:02 CEST | jreher | Updated APD location via API. |
11. Aug 2020 17:26:44 CEST | jreher | Updated APD characteristics via API. |
27. Nov 2019 19:36:38 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:14:21 CET | jreher | Updated box and position via API. |
04. Jul 2019 11:11:28 CEST | jreher | Updated APD location via API. |
12. Jun 2019 16:48:38 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 16:33:34 CEST | jreher | Updated APD batch assignment via API. |
28. Apr 2014 15:40:36 CEST | Tobias | Imported from Hamamatsu datasheet. |