RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1405015425 - Archived data from Fri, 16. April 2021 22:00:07 CEST


This is all the information about APD 1405015425. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1405015425
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D07
Break-through voltage: 416 V
Voltage for Gain 100 (T=+25°C): 386.8 V
Dark current: 4.9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 348
Position in Box: 20
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 372
Position in grid: 2
Arrival for irradiation: 20. Dec 2016
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 387.3590357 V     T = -25 °C: 351.1746426 V
Voltage for Gain 150: T = +20 °C: 395.3033905 V     T = -25 °C: 358.7043151 V
Voltage for Gain 200: T = +20 °C: 399.7067688 V     T = -25 °C: 362.923319 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.44798683 V-1     T = -25 °C: 4.761586525 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.605870443 V-1     T = -25 °C: 9.596358855 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.91353698 V-1     T = -25 °C: 15.10110315 V-1
Break-through voltage: T = +20 °C: 415.3758763 V     T = -25 °C: 378.6417586 V
   
Notes:


Version history

Time Author Change comment
15. Nov 2022 12:53:16 CET oafedulidis Assigned to capsule by script
16. Apr 2021 22:00:07 CEST jreher Updated APD characteristics via API.
15. Apr 2021 17:00:56 CEST jreher Updated box and position via API.
05. Feb 2021 11:32:56 CET jreher Updated box and position via API.
17. Aug 2020 14:03:37 CEST vwerner Updated APD batch assignment via API.
11. Aug 2020 17:54:36 CEST jreher Updated APD location via API.
20. Dec 2016 10:26:16 CET markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:13 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:32:21 CEST Tobias Imported from Hamamatsu datasheet.