RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1405015425


This is all the information about APD 1405015425. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1405015425
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 0805007546/1405015425
Unit: #3649 (barcode 1309026135)
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: red
   
Manufacturer information:  
Wafer position: D07
Break-through voltage: 416 V
Voltage for Gain 100 (T=+25°C): 386.8 V
Dark current: 4.9 nA
   
Screening Logistics:  
Available: No
Storage Box: 348
Position in Box: 20
EP1 batch: none
EP1 batch after irradiation: 10528
   
Shipment:  
Grid number: 372
Position in grid: 2
Arrival for irradiation: 20. Dec 2016
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 387.3590357 V     T = -25 °C: 351.1746426 V
Voltage for Gain 150: T = +20 °C: 395.3033905 V     T = -25 °C: 358.7043151 V
Voltage for Gain 200: T = +20 °C: 399.7067688 V     T = -25 °C: 362.923319 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.44798683 V-1     T = -25 °C: 4.761586525 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.605870443 V-1     T = -25 °C: 9.596358855 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.91353698 V-1     T = -25 °C: 15.10110315 V-1
Break-through voltage: T = +20 °C: 415.3758763 V     T = -25 °C: 378.6417586 V
   
Notes:


Characteristics

Temperature Measurement Notes
No characteristics available!


Upload new characteristic...

Progression of the current during irradiation

Upload time Notes
No data available!


Upload new progression data...

Version history

Time Author Change comment
15. Nov 2022 12:53:16 CET oafedulidis Assigned to capsule by script
16. Apr 2021 22:00:07 CEST jreher Updated APD characteristics via API.
15. Apr 2021 17:00:56 CEST jreher Updated box and position via API.
05. Feb 2021 11:32:56 CET jreher Updated box and position via API.
17. Aug 2020 14:03:37 CEST vwerner Updated APD batch assignment via API.
11. Aug 2020 17:54:36 CEST jreher Updated APD location via API.
20. Dec 2016 10:26:16 CET markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:13 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:32:21 CEST Tobias Imported from Hamamatsu datasheet.