RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1405015423 - Archived data from Tue, 20. December 2016 10:26:16 CET


This is all the information about APD 1405015423. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1405015423
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: unknown
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: A09
Break-through voltage: 414 V
Voltage for Gain 100 (T=+25°C): 387.6 V
Dark current: 5.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 348
Position in Box: 18
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 372
Position in grid: 0
Arrival for irradiation: 20. Dec 2016
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 150: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 200: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 100: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 150: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 200: T = +20 °C: none     T = -25 °C: none
Break-through voltage: T = +20 °C: none     T = -25 °C: none
   
Notes:


Version history

Time Author Change comment
16. Nov 2021 10:39:48 CET oafedulidis Assigned to capsule by script
21. Apr 2021 11:02:32 CEST jreher Updated box and position via API.
16. Apr 2021 22:00:07 CEST jreher Updated APD characteristics via API.
05. Feb 2021 11:32:55 CET jreher Updated box and position via API.
17. Aug 2020 14:03:37 CEST vwerner Updated APD batch assignment via API.
11. Aug 2020 17:54:36 CEST jreher Updated APD location via API.
20. Dec 2016 10:26:16 CET markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:13 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:32:21 CEST Tobias Imported from Hamamatsu datasheet.