RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1405015423 - Archived data from Wed, 21. April 2021 11:02:32 CEST


This is all the information about APD 1405015423. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1405015423
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: A09
Break-through voltage: 414 V
Voltage for Gain 100 (T=+25°C): 387.6 V
Dark current: 5.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 348
Position in Box: 18
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 372
Position in grid: 0
Arrival for irradiation: 20. Dec 2016
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 386.6182619 V     T = -25 °C: 350.6492182 V
Voltage for Gain 150: T = +20 °C: 394.5458941 V     T = -25 °C: 358.1773434 V
Voltage for Gain 200: T = +20 °C: 398.9262311 V     T = -25 °C: 362.4124125 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.372188129 V-1     T = -25 °C: 4.630831828 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.526305095 V-1     T = -25 °C: 9.242254155 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.93076135 V-1     T = -25 °C: 14.50271202 V-1
Break-through voltage: T = +20 °C: 412.7371483 V     T = -25 °C: 376.8764618 V
   
Notes:


Version history

Time Author Change comment
16. Nov 2021 10:39:48 CET oafedulidis Assigned to capsule by script
21. Apr 2021 11:02:32 CEST jreher Updated box and position via API.
16. Apr 2021 22:00:07 CEST jreher Updated APD characteristics via API.
05. Feb 2021 11:32:55 CET jreher Updated box and position via API.
17. Aug 2020 14:03:37 CEST vwerner Updated APD batch assignment via API.
11. Aug 2020 17:54:36 CEST jreher Updated APD location via API.
20. Dec 2016 10:26:16 CET markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:13 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:32:21 CEST Tobias Imported from Hamamatsu datasheet.