Show Hamamatsu Avalanche Photo Diode 1404015380 - Archived data from Wed, 03. February 2021 18:19:28 CET
This is all the information about APD 1404015380. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1404015380 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | C05 |
Break-through voltage: | 421 V |
Voltage for Gain 100 (T=+25°C): | 392.8 V |
Dark current: | 7.7 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 42 |
Position in Box: | 49 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 369 |
Position in grid: | 18 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | 26. Nov 2018 |
Return for assembly: | none |
Irradiation: | |
Date: | 22. Nov 2018 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 23. Nov 2018 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 392.7911558 V T = -25 °C: 356.3733787 V |
Voltage for Gain 150: | T = +20 °C: 400.6940277 V T = -25 °C: 364.1132108 V |
Voltage for Gain 200: | T = +20 °C: 405.1545844 V T = -25 °C: 368.4717496 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 5.2400734 V-1 T = -25 °C: 4.554237772 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.654908546 V-1 T = -25 °C: 8.435764798 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 13.91508911 V-1 T = -25 °C: 15.08311956 V-1 |
Break-through voltage: | T = +20 °C: 420.5501932 V T = -25 °C: 384.2302955 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 10:53:41 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:19:28 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:26:37 CEST | jreher | Updated APD characteristics via API. |
27. Nov 2019 19:36:28 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:14:17 CET | jreher | Updated box and position via API. |
04. Jul 2019 11:11:21 CEST | jreher | Updated APD location via API. |
12. Jun 2019 16:48:35 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 16:33:31 CEST | jreher | Updated APD batch assignment via API. |
26. Nov 2018 14:42:14 CET | markus.moritz | |
29. Sep 2017 13:34:43 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:29:11 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:31:22 CEST | Tobias | Imported from Hamamatsu datasheet. |