Subdetector specification:  
Serial: 1403015294
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 1403015294/2408026491
Unit: #1540 (barcode 1309016433)
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: blue
   
Manufacturer information:  
Wafer position: G05
Break-through voltage: 414 V
Voltage for Gain 100 (T=+25°C): 385.6 V
Dark current: 5.7 nA
   
Screening Logistics:  
Available: No
Storage Box: 32
Position in Box: 46
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 365
Position in grid: 17
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: 26. Nov 2018
Return for assembly: none
   
Irradiation:  
Date: 22. Nov 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 23. Nov 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 386.2589747 V     T = -25 °C: 350.3623581 V
Voltage for Gain 150: T = +20 °C: 394.1454679 V     T = -25 °C: 357.8714736 V
Voltage for Gain 200: T = +20 °C: 398.5762043 V     T = -25 °C: 362.0931427 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.41681472 V-1     T = -25 °C: 4.647125161 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.676818496 V-1     T = -25 °C: 8.781309548 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.56659489 V-1     T = -25 °C: 14.39621029 V-1
Break-through voltage: T = +20 °C: 412.5679899 V     T = -25 °C: 377.6022776 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:52:02 CET jreher Updated box and position via API.
03. Feb 2021 18:18:08 CET jreher Updated box and position via API.
08. Dec 2020 17:06:59 CET jreher Assigned to capsule by script
17. Aug 2020 16:01:00 CEST vwerner Updated box and position via API.
11. Aug 2020 17:24:57 CEST jreher Updated APD characteristics via API.
28. Nov 2019 12:22:16 CET jreher Updated APD location via API.
25. Nov 2019 17:13:26 CET jreher Updated box and position via API.
13. Jun 2019 11:28:49 CEST jreher Updated APD location via API.
12. Jun 2019 16:47:50 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:32:45 CEST jreher Updated APD batch assignment via API.
26. Nov 2018 14:48:33 CET markus.moritz
29. Sep 2017 12:35:58 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:08 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:31:20 CEST Tobias Imported from Hamamatsu datasheet.