Show Hamamatsu Avalanche Photo Diode 1403015278 - Archived data from Tue, 11. August 2020 17:24:54 CEST
This is all the information about APD 1403015278. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1403015278 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | G08 |
Break-through voltage: | 418 V |
Voltage for Gain 100 (T=+25°C): | 389.2 V |
Dark current: | 6.4 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 32 |
Position in Box: | 31 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 365 |
Position in grid: | 2 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | 26. Nov 2018 |
Return for assembly: | none |
Irradiation: | |
Date: | 22. Nov 2018 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 23. Nov 2018 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 389.6957744 V T = -25 °C: 353.5146919 V |
Voltage for Gain 150: | T = +20 °C: 397.6365793 V T = -25 °C: 361.162304 V |
Voltage for Gain 200: | T = +20 °C: 402.0710601 V T = -25 °C: 365.4788498 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.618117577 V-1 T = -25 °C: 4.832892496 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.653956266 V-1 T = -25 °C: 9.057228877 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 15.28107344 V-1 T = -25 °C: 14.21195896 V-1 |
Break-through voltage: | T = +20 °C: 417.7973036 V T = -25 °C: 381.2712235 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 10:52:00 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:18:06 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:24:54 CEST | jreher | Updated APD characteristics via API. |
28. Nov 2019 12:22:15 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:13:24 CET | jreher | Updated box and position via API. |
13. Jun 2019 11:28:48 CEST | jreher | Updated APD location via API. |
12. Jun 2019 16:47:48 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 16:32:43 CEST | jreher | Updated APD batch assignment via API. |
26. Nov 2018 14:56:55 CET | markus.moritz | |
29. Sep 2017 12:35:57 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:29:08 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:31:19 CEST | Tobias | Imported from Hamamatsu datasheet. |