RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1403015261 - Archived data from Tue, 11. August 2020 17:58:23 CEST


This is all the information about APD 1403015261. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1403015261
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C14
Break-through voltage: 421 V
Voltage for Gain 100 (T=+25°C): 392.9 V
Dark current: 8.9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 307
Position in Box: 30
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 364
Position in grid: 7
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: 27. Oct 2017
Return for assembly: none
   
Irradiation:  
Date: 25. Oct 2017
Dose used: 45 Gy
Temperature: 20 °C
Position: 3
Bias voltage: 392.9 V     (connected)
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 393.0474275 V     T = -25 °C: 356.7433585 V
Voltage for Gain 150: T = +20 °C: 401.0393543 V     T = -25 °C: 364.4064324 V
Voltage for Gain 200: T = +20 °C: 405.4884741 V     T = -25 °C: 368.7037937 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.486484368 V-1     T = -25 °C: 4.840644977 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.794129302 V-1     T = -25 °C: 8.777728701 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.28091113 V-1     T = -25 °C: 15.24048348 V-1
Break-through voltage: T = +20 °C: 420.9798428 V     T = -25 °C: 384.2901437 V
   
Notes:


Version history

Time Author Change comment
15. Nov 2022 12:52:47 CET oafedulidis Assigned to capsule by script
09. Dec 2021 13:11:01 CET oafedulidis Updated box and position via API.
05. Feb 2021 11:28:05 CET jreher Updated box and position via API.
11. Aug 2020 17:58:23 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:44:41 CEST jreher Updated APD location via API.
21. Jul 2020 14:44:31 CEST jreher Updated box and position via API.
19. Dec 2019 16:35:44 CET spankonin Updated APD batch assignment via API.
19. Dec 2019 15:18:46 CET jreher Updated box and position via API.
27. Oct 2017 10:38:08 CEST markus.moritz Entered shipped after irradiation date.
26. Oct 2017 16:27:44 CEST markus.moritz Entered irradiation information.
29. Sep 2017 12:17:00 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:07 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:31:19 CEST Tobias Imported from Hamamatsu datasheet.