RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1403015254 - Archived data from Tue, 11. August 2020 17:58:22 CEST


This is all the information about APD 1403015254. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1403015254
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E14
Break-through voltage: 420 V
Voltage for Gain 100 (T=+25°C): 391.9 V
Dark current: 11 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 307
Position in Box: 24
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 364
Position in grid: 1
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: 27. Oct 2017
Return for assembly: none
   
Irradiation:  
Date: 25. Oct 2017
Dose used: 45 Gy
Temperature: 20 °C
Position: 3
Bias voltage: 391.9 V     (connected)
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 392.2587657 V     T = -25 °C: 355.7627382 V
Voltage for Gain 150: T = +20 °C: 400.2182041 V     T = -25 °C: 363.41347 V
Voltage for Gain 200: T = +20 °C: 404.6390614 V     T = -25 °C: 367.7077591 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.450348709 V-1     T = -25 °C: 4.855198857 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.668562928 V-1     T = -25 °C: 8.7345864 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.01769197 V-1     T = -25 °C: 15.23094018 V-1
Break-through voltage: T = +20 °C: 420.0291928 V     T = -25 °C: 383.216107 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:28:04 CET jreher Updated box and position via API.
11. Aug 2020 17:58:22 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:44:40 CEST jreher Updated APD location via API.
21. Jul 2020 14:44:30 CEST jreher Updated box and position via API.
19. Dec 2019 16:35:44 CET spankonin Updated APD batch assignment via API.
19. Dec 2019 15:18:45 CET jreher Updated box and position via API.
27. Oct 2017 10:38:08 CEST markus.moritz Entered shipped after irradiation date.
26. Oct 2017 16:27:44 CEST markus.moritz Entered irradiation information.
29. Sep 2017 12:17:00 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:07 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:31:19 CEST Tobias Imported from Hamamatsu datasheet.