Show Hamamatsu Avalanche Photo Diode 1403015252 - Archived data from Tue, 21. July 2020 14:44:54 CEST


This is all the information about APD 1403015252. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1403015252
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D03
Break-through voltage: 417 V
Voltage for Gain 100 (T=+25°C): 388 V
Dark current: 10.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 308
Position in Box: 7
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 363
Position in grid: 19
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: 03. Nov 2017
Return for assembly: none
   
Irradiation:  
Date: 26. Oct 2017
Dose used: 45 Gy
Temperature: 20 °C
Position: 2
Bias voltage: 388 V     (connected)
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 150: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 200: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 100: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 150: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 200: T = +20 °C: none     T = -25 °C: none
Break-through voltage: T = +20 °C: none     T = -25 °C: none
   
Notes:


Version history

Time Author Change comment
27. Aug 2021 11:12:05 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:28:10 CET jreher Updated box and position via API.
11. Aug 2020 17:58:28 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:44:54 CEST jreher Updated APD location via API.
21. Jul 2020 14:44:44 CEST jreher Updated box and position via API.
19. Dec 2019 16:36:09 CET spankonin Updated APD batch assignment via API.
19. Dec 2019 15:18:52 CET jreher Updated box and position via API.
03. Nov 2017 16:13:01 CET markus.moritz Entered shipped after irradiation date.
26. Oct 2017 16:36:09 CEST markus.moritz Entered irradiation information.
29. Sep 2017 11:34:21 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:07 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:31:19 CEST Tobias Imported from Hamamatsu datasheet.